In The Winery


                  alcohols.                                         15. Close the stopcock and repeat steps 3 through
                                                                        14 above.
                             Procedure for Wine
                                                                    16. From experience the operator will easily be able
               1.  We have calibrated the unit and have wines           to run about 5 tests with these units before the
                  ready to test.                                        cool water in the upper condenser needs to be
                                                                        refreshed and the alcohol burner needs to be
               2.  Make sure the upper condenser is filled with         filled with ethyl alcohol.  (Be careful as alcohol
                  cool water.                                           is flammable).


               3.  Fill the glass cylinder supplied to the line “vin”                  Calculation
                  (roughly 50 milliliters) with the wine you plan to
                  test.                                             As you can see there is no real calculation here.
                                                                    Just using the slide rule circular chart and making
               4.  Place this amount of wine in the boiling cham-   sure to use a steady hand while making future
                  ber once again through the thermometer ori-       readings.  Make sure not to accidently move the
                  fice.                                             inside circle on the “slide rule” as readings will be
                                                                    affected.  If this does happen you will need to relo-
               5.  Replace the thermometer in that orifice imme-    cate the chart to the recorded distilled water boil-
                  diately.                                          ing point or actually re-establish that data point via
                                                                    the steps under calibration above.
               6.  Light and place the burner under the chimney
                  to heat the wine sample.
                                                                                   Other Helpful Tips
               7.  Wait about 3 to 5 minutes to hear the similar
                  rumble in the unit as noted previously above in   Residual sugar :  The boiling point of a wine is
                  step 5 under the distilled water calibration sec-  raised if the wine has a perceivable residual sugar.
                  tion.                                             The raising of the boiling point temperature gives a
                                                                    false low alcohol reading for the wine.  A wine high-
               8.  Watch the mercury rise and wait patiently for it   er in alcohol will boil at a lower temperature due to
                  to steady on a reading.  It will be jumpy at first   the fact alcohol has a low boiling point.  Sugar will
                  but allow it to remain on one reading, steady,    interfere with the readings
                  for about 30 seconds.
                                                                    Reproducible results :  If this is your first time using
               9.  Record that boiling point.                       one of these units be sure to run several tests on
                                                                    the same wine to make sure you can achieve sim-
               10. Remove the burner and blow it out.               ilar results with each test.  If you can’t achieve the
                                                                    same results dig deeper to look for errors.
               11. Carefully look on the calibration circular slide
                  rule for that temperature reading.                Spot check your results from time to time with a
                                                                    competent outside lab to see if results are within
               12. Follow the chart carefully to see what alcohol   ranges expected.  If not – look for sources of error.
                  level that reflects.
                                                                    While performing the test make sure to calibrate
               13. Record that alcohol reading in the proper places  the unit with distilled water if you notice atmo-
                  for your records.                                 spheric changes taking place outside.  At a min-
                                                                    imum it may be best to calibrate the unit every
               14. Carefully dump the boiled wine sample in a lab   three hours or so.  Recall to flush the chamber out
                  sink or other container.  Recall this is very hot   with upcoming wine sample after calibrating with
                  and know that you may need to gently tilt the     distilled water to avoid false / water diluted read-
                  unit toward the stopcock opening to get the       ings.
                  entire sample out.
                                                                    Typically these units are very foolproof and last for